Airpreheater is a general term and represents any heater designed to heat air. It may be for residential use namely for room heating, house heating, etc. by means of gas, electricity or oil etc. In the present context reference is to the airpreheaters (Fossil_fuel_power_plant#Boiler_operation) used in steam generators (boilers) for generation of electricity in Power Generation Utilities. The location of the rotating type air preheater in the Boiler/TG cycle is shown in the typical schematic diagram. Image:Dores-Boiler Cycle diag1.png

AttributesValues
rdfs:label
  • Air preheater
rdfs:comment
  • Airpreheater is a general term and represents any heater designed to heat air. It may be for residential use namely for room heating, house heating, etc. by means of gas, electricity or oil etc. In the present context reference is to the airpreheaters (Fossil_fuel_power_plant#Boiler_operation) used in steam generators (boilers) for generation of electricity in Power Generation Utilities. The location of the rotating type air preheater in the Boiler/TG cycle is shown in the typical schematic diagram. Image:Dores-Boiler Cycle diag1.png
sameAs
dcterms:subject
dbkwik:engineering...iPageUsesTemplate
abstract
  • Airpreheater is a general term and represents any heater designed to heat air. It may be for residential use namely for room heating, house heating, etc. by means of gas, electricity or oil etc. In the present context reference is to the airpreheaters (Fossil_fuel_power_plant#Boiler_operation) used in steam generators (boilers) for generation of electricity in Power Generation Utilities. The purpose of the air preheater is to recover the heat from the flue gas(exhaust gases) from the boiler to improve boiler efficiency. Incidentally the gases are sent to the chimney or stack at lowered temperature so that the design of the ducting and the stack becomes simplified. Also it controls the temperature of gases coming out of the stack. The location of the rotating type air preheater in the Boiler/TG cycle is shown in the typical schematic diagram. Image:Dores-Boiler Cycle diag1.png
Alternative Linked Data Views: ODE     Raw Data in: CXML | CSV | RDF ( N-Triples N3/Turtle JSON XML ) | OData ( Atom JSON ) | Microdata ( JSON HTML) | JSON-LD    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3217, on Linux (x86_64-pc-linux-gnu), Standard Edition
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2012 OpenLink Software