You can use the box below to create new pages for this mini-wiki. preload=Mass Spectrometer/preload editintro=Mass Spectrometer/editintro width=25 How a mass spectrometer works The basic principle If something is moving and you subject it to a sideways force, instead of moving in a straight line, it will move in a curve - deflected out of its original path by the sideways force. But suppose instead, you tried to deflect a table tennis ball travelling at the same speed as the cannonball using the same jet of water. Because this ball is so light, you will get a huge deflection. The sequence is :

AttributesValues
rdfs:label
  • Mass Spectrometer
  • Mass spectrometer
rdfs:comment
  • You can use the box below to create new pages for this mini-wiki. preload=Mass Spectrometer/preload editintro=Mass Spectrometer/editintro width=25 How a mass spectrometer works The basic principle If something is moving and you subject it to a sideways force, instead of moving in a straight line, it will move in a curve - deflected out of its original path by the sideways force. But suppose instead, you tried to deflect a table tennis ball travelling at the same speed as the cannonball using the same jet of water. Because this ball is so light, you will get a huge deflection. The sequence is :
  • A mass spectrometer was a device invented in the 20th century on Earth that was still used in the 24th century aboard Federation starships, and that could measure the mass-to-charge ratio of ions. When Doctor Beverly Crusher was caught in a warp bubble created by her son, she imagined Geordi La Forge running a mass spectrometer on all particulates in sickbay where she saw an energy vortex, all to no avail. (TNG: "Remember Me" )
dcterms:subject
dbkwik:memory-alph...iPageUsesTemplate
dbkwik:scratch-pad...iPageUsesTemplate
dbkwik:scratchpad/...iPageUsesTemplate
abstract
  • You can use the box below to create new pages for this mini-wiki. preload=Mass Spectrometer/preload editintro=Mass Spectrometer/editintro width=25 How a mass spectrometer works The basic principle If something is moving and you subject it to a sideways force, instead of moving in a straight line, it will move in a curve - deflected out of its original path by the sideways force. Suppose you had a cannonball travelling past you and you wanted to deflect it as it went by you. All you've got is a jet of water from a hose-pipe that you can squirt at it. Frankly, its not going to make a lot of difference! Because the cannonball is so heavy, it will hardly be deflected at all from its original course. But suppose instead, you tried to deflect a table tennis ball travelling at the same speed as the cannonball using the same jet of water. Because this ball is so light, you will get a huge deflection. The amount of deflection you will get for a given sideways force depends on the mass of the ball. If you knew the speed of the ball and the size of the force, you could calculate the mass of the ball if you knew what sort of curved path it was deflected through. The less the deflection, the heavier the ball. You can apply exactly the same principle to atomic sized particles. An outline of what happens in a mass spectrometer Atoms can be deflected by magnetic fields - provided the atom is first turned into an ion. Electrically charged particles are affected by a magnetic field although electrically neutral ones aren't. The sequence is : Stage 1: Ionisation The atom is ionised by knocking one or more electrons off to give a positive ion. This is true even for things which you would normally expect to form negative ions (chlorine, for example) or never form ions at all (argon, for example). Mass spectrometers always work with positive ions. Stage 2: Acceleration The ions are accelerated so that they all have the same kinetic energy. Stage 3: Deflection The ions are then deflected by a magnetic field according to their masses. The lighter they are, the more they are deflected. The amount of deflection also depends on the number of positive charges on the ion - in other words, on how many electrons were knocked off in the first stage. The more the ion is charged, the more it gets deflected. Stage 4: Detection The beam of ions passing through the machine is detected electrically. <a href="http://i6.tinypic.com/143gefd.gif">http://i6.tinypic.com/143gefd.gif</a> Understanding what's going on The need for a vacuum It's important that the ions produced in the ionisation chamber have a free run through the machine without hitting air molecules. Ionisation <a href="http://i5.tinypic.com/143gewp.gif">http://i5.tinypic.com/143gewp.gif</a> The vaporised sample passes into the ionisation chamber. The electrically heated metal coil gives off electrons which are attracted to the electron trap which is a positively charged plate. The particles in the sample (atoms or molecules) are therefore bombarded with a stream of electrons, and some of the collisions are energetic enough to knock one or more electrons out of the sample particles to make positive ions. Most of the positive ions formed will carry a charge of +1 because it is much more difficult to remove further electrons from an already positive ion. These positive ions are persuaded out into the rest of the machine by the ion repeller which is another metal plate carrying a slight positive charge. <a href="http://i5.tinypic.com/143gf83.gif">http://i5.tinypic.com/143gf83.gif</a> The positive ions are repelled away from the very positive ionisation chamber and pass through three slits, the final one of which is at 0 volts. The middle slit carries some intermediate voltage. All the ions are accelerated into a finely focused beam. Deflection <a href="http://i5.tinypic.com/143gfg2.gif">http://i5.tinypic.com/143gfg2.gif</a> Different ions are deflected by the magnetic field by different amounts. The amount of deflection depends on: * the mass of the ion. Lighter ions are deflected more than heavier ones. * the charge on the ion. Ions with 2 (or more) positive charges are deflected more than ones with only 1 positive charge. These two factors are combined into the mass/charge ratio. Mass/charge ratio is given the symbol m/z (or sometimes m/e). For example, if an ion had a mass of 28 and a charge of 1+, its mass/charge ratio would be 28. An ion with a mass of 56 and a charge of 2+ would also have a mass/charge ratio of 28. In the last diagram, ion stream A is most deflected - it will contain ions with the smallest mass/charge ratio. Ion stream C is the least deflected - it contains ions with the greatest mass/charge ratio. It makes it simpler to talk about this if we assume that the charge on all the ions is 1+. Most of the ions passing through the mass spectrometer will have a charge of 1+, so that the mass/charge ratio will be the same as the mass of the ion. Assuming 1+ ions, stream A has the lightest ions, stream B the next lightest and stream C the heaviest. Lighter ions are going to be more deflected than heavy ones. Detection Only ion stream B makes it right through the machine to the ion detector. The other ions collide with the walls where they will pick up electrons and be neutralised. Eventually, they get removed from the mass spectrometer by the vacuum pump. <a href="http://i5.tinypic.com/143gfvp.gif">http://i5.tinypic.com/143gfvp.gif</a> When an ion hits the metal box, its charge is neutralised by an electron jumping from the metal on to the ion (right hand diagram). That leaves a space amongst the electrons in the metal, and the electrons in the wire shuffle along to fill it. A flow of electrons in the wire is detected as an electric current which can be amplified and recorded. The more ions arriving, the greater the current. Detecting the other ions How might the other ions be detected - those in streams A and C which have been lost in the machine? Remember that stream A was most deflected - it has the smallest value of m/z (the lightest ions if the charge is 1+). To bring them on to the detector, you would need to deflect them less - by using a smaller magnetic field (a smaller sideways force). To bring those with a larger m/z value (the heavier ions if the charge is +1) on to the detector you would have to deflect them more by using a larger magnetic field. If you vary the magnetic field, you can bring each ion stream in turn on to the detector to produce a current which is proportional to the number of ions arriving. The mass of each ion being detected is related to the size of the magnetic field used to bring it on to the detector. The machine can be calibrated to record current (which is a measure of the number of ions) against m/z directly. The mass is measured on the 12C scale. What the mass spectrometer output looks like The output from the chart recorder is usually simplified into a "stick diagram". This shows the relative current produced by ions of varying mass/charge ratio. The stick diagram for molybdenum looks like this: <a href="http://i6.tinypic.com/143gg9z.gif">http://i6.tinypic.com/143gg9z.gif</a> You may find diagrams in which the vertical axis is labelled as either "relative abundance" or "relative intensity". Whichever is used, it means the same thing. The vertical scale is related to the current received by the chart recorder - and so to the number of ions arriving at the detector: the greater the current, the more abundant the ion. As you will see from the diagram, the commonest ion has a mass/charge ratio of 98. Other ions have mass/charge ratios of 92, 94, 95, 96, 97 and 100. That means that molybdenum consists of 7 different isotopes. Assuming that the ions all have a charge of 1+, that means that the masses of the 7 isotopes on the carbon-12 scale are 92, 94, 95, 96, 97, 98 and 100.
  • A mass spectrometer was a device invented in the 20th century on Earth that was still used in the 24th century aboard Federation starships, and that could measure the mass-to-charge ratio of ions. When Doctor Beverly Crusher was caught in a warp bubble created by her son, she imagined Geordi La Forge running a mass spectrometer on all particulates in sickbay where she saw an energy vortex, all to no avail. (TNG: "Remember Me" ) When the the dilithium chamber hatch aboard the USS Enterprise-D exploded in 2367, La Forge and Data did mass spectrometer readings of the remains of the hatch to see if a chemical explosive was used, but did not find anything suspicious. They later, by means of a microtomographic analysis of the dilithium chamber and the hatch mounting, detected sub-micron fractures in the metal casing, a breakdown in the atomic cohesive structure. This meant that neutron fatigue caused the explosion, not sabotage by the Klingon exobiologist J'Dan, as was originally suspected. (TNG: "The Drumhead" ) In 2369, while searching for a cure for the aphasia virus, Dr. Julian Bashir performed a mass spectrometry analysis on a patient's tissue, which revealed a slight genetic abnormality. (DS9: "Babel")
Alternative Linked Data Views: ODE     Raw Data in: CXML | CSV | RDF ( N-Triples N3/Turtle JSON XML ) | OData ( Atom JSON ) | Microdata ( JSON HTML) | JSON-LD    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3217, on Linux (x86_64-pc-linux-gnu), Standard Edition
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2012 OpenLink Software